Views: 26 Author: Lion Publish Time: 2026-11-28 Origin: Site
When buying a desktop AC/DC power adapter, most buyers first check the output voltage, output current, and rated power. However, the AC power inlet is also an important part of the product specification.
C6, C8, C14, and C18 are four common AC power inlet types covered by the IEC 60320 standard. They differ in shape, number of pins, and protective earth connection. Each type also requires a matching connector on the AC power cord.
Choosing the correct AC power inlet helps prevent connection problems and ensures that the adapter's AC input matches its electrical safety design.
This guide explains the differences between these four types and what OEM buyers should check before ordering a desktop power adapter.
An AC power inlet is the connector mounted on a power adapter or other electrical equipment. The AC power cord has a matching connector that plugs into it.
C6, C8, C14, and C18 AC power inlets have different pin arrangements and protective earth connections.
| AC power inlet | Matching AC power cord connector | Number of pins | Protective Earth (PE) | Common shape |
|---|---|---|---|---|
| C6 | C5 | 3 | Yes | Cloverleaf |
| C8 | C7 | 2 | No | Figure-eight |
| C14 | C13 | 3 | Yes | Rectangular |
| C18 | C17 | 2 | No | Two-pole rectangular |
C6 and C8
A C6 AC power inlet has three pins, including a protective earth pin. It connects to a C5 AC power cord connector, which has a cloverleaf shape.
A C8 AC power inlet has two pins and no protective earth connection. It connects to a C7 AC power cord connector, which has a figure-eight shape.
C14 and C18
A C14 AC power inlet has three pins, including a protective earth pin. It connects to a C13 AC power cord connector.
A C18 AC power inlet has two pins and no protective earth connection. It connects to a C17 AC power cord connector.
These connectors are not interchangeable. For example, a C14 AC power inlet requires a C13 connector, not a C17 connector.

The AC power inlet type is related to the adapter's electrical protection class. Under the IEC 60320 system, C6 and C14 couplers are used for Class I equipment, while C8 and C18 couplers are used for Class II equipment.
To understand this difference, buyers should know how Class I and Class II equipment protect users from electric shock.
Class I equipment uses basic insulation to protect users from electric shock. Accessible metal parts that could become live if an insulation fault occurs are connected to Protective Earth (PE).
If a fault causes a live wire to touch an accessible metal part, the PE connection provides a path for fault current. This helps the protective device cut off the power.
A Class I adapter therefore needs a protective earth connection as part of its electrical safety design.
Class II equipment uses double insulation or reinforced insulation to protect users from electric shock. It does not rely on a protective earth connection.
The double-square symbol on the product label identifies Class II equipment.
Because Class II equipment does not require a PE connection, it uses a two-pin AC power inlet designed for the corresponding IEC 60320 connector.
The common IEC 60320 combinations are:
Class I: C6 with C5, or C14 with C13. These connectors include a protective earth connection.
Class II: C8 with C7, or C18 with C17. These connectors do not include a protective earth connection.
The adapter's protection class must still be confirmed through its complete electrical design and safety testing. The number of pins alone does not establish the protection class of the entire adapter.

No. A higher output wattage does not automatically mean that a power adapter must use a C14 AC power inlet.
The correct AC power inlet must match the adapter's input voltage and current, grounding design, and electrical safety requirements.
For example, two desktop adapters with similar DC output power may use different AC power inlets because their input current and electrical protection designs are different.
Before choosing an AC power inlet, buyers should check the following:
AC input voltage and frequency
Check the adapter's rated AC input range and frequency, such as 100–240V AC, 50/60Hz. The AC power inlet and AC power cord must be rated for the specified input.
AC input current
Check the adapter's rated input current. The AC power inlet and AC power cord must have suitable current ratings for the actual operating conditions. Do not choose an AC power inlet based only on the adapter's DC output wattage.
Protective earth connection
Specify whether the adapter's electrical safety design requires Protective Earth (PE). This determines which AC power inlet type is appropriate for the design.
Adapter housing
Check the available space on the adapter housing and how the AC power inlet will be mounted. The inlet must fit the housing and maintain the required spacing between electrical parts.
AC power cord and destination country
Specify the required AC wall plug and AC power cord connector for the destination country. For example, EU and US wall plugs have different designs.
Safety standards and certification
The adapter, AC power inlet, and AC power cord must meet the relevant safety standards. If the AC power inlet type changes during product development, the manufacturer should check whether additional safety testing or certification testing is needed.
When requesting a customized desktop AC/DC power adapter, buyers should provide the following specifications before sample production.
| Item | Information to specify |
|---|---|
| DC output voltage | Required output voltage |
| DC output current | Required output current |
| Rated output power | Total DC output power |
| AC input voltage | Required input voltage range |
| AC input frequency | 50Hz, 60Hz, or 50/60Hz |
| AC input current | Rated input current |
| Electrical protection class | Class I or Class II |
| AC power inlet | C6, C8, C14, or C18 |
| AC power cord connector | C5, C7, C13, or C17 |
| AC wall plug | EU, US, UK, AU, or another type |
| Safety certification | Required certificates for the destination country |
| Adapter housing | Available space and inlet mounting position |
Buyers should also specify whether they need a detachable AC power cord or a fixed AC input cable.
For example, a buyer may request a desktop adapter with a 100–240V AC input, a specified DC output, and a C14 AC power inlet with a matching C13 AC power cord.
Before making the sample, the manufacturer should check the adapter's input current, PE connection, housing dimensions, and safety standards.
Providing these details at the beginning helps prevent incorrect connections and reduces unnecessary sample changes.
Mistake 1: Choosing an AC power inlet based only on output wattage
The adapter's output wattage does not determine the AC power inlet by itself. Buyers must also check AC input current, protective earth requirements, and the complete electrical safety design.
Mistake 2: Mixing up AC power inlet and AC power cord connector names
C6 connects to C5, C8 to C7, C14 to C13, and C18 to C17. Check both connector types before ordering the AC power cord.
Mistake 3: Assuming the number of pins proves the adapter's protection class
Three-pin and two-pin AC power inlets have different protective earth arrangements. However, the adapter's protection class must be established through its complete electrical design and safety testing.
Mistake 4: Ignoring the destination country's AC power cord requirements
The AC wall plug and AC power cord must match the destination country. Buyers should specify these details before mass production to avoid shipping products with the wrong power cord.
Q1: What is the difference between C8 and C7?
C8 is the inlet on the adapter, while C7 is the matching connector on the detachable power cord.
Q2: What is the difference between C6 and C8?
C6 has three contacts, including protective earth. C8 has two contacts and no protective earth. C6 uses a C5 cord connector, while C8 uses C7.
Q3: Is C14 always better than C8?
No. They have different contact and grounding configurations. The correct choice depends on the power supply design, input requirements, safety architecture, and application.
Q4: Does a C14 inlet mean the adapter is Class I?
Not automatically. C14 provides a protective earth contact, but the complete grounding arrangement and safety construction determine the protection classification.
Q5: Can a two-pin adapter be Class II?
Yes. Many two-pin adapters are designed as Class II equipment using double or reinforced insulation. The safety class must be confirmed from the actual product design and applicable evaluation.
Q6: Should I order the power cord together with the adapter?
For a specific destination market, specifying the correct cord at the same time helps avoid connector, electrical-rating, and regional plug mismatches. Confirm whether the cord is included in the quotation.
C6, C8, C14, and C18 AC power inlets differ in pin arrangement, protective earth connection, shape, and matching AC power cord connector.
Under the IEC 60320 connector system, C6 and C14 are used for Class I equipment, while C8 and C18 are used for Class II equipment. The correct AC power inlet must also match the adapter's input voltage and current, electrical safety design, AC power cord, and destination country.
Checking these details before sample production helps prevent connection problems and reduces unnecessary sample changes.
Sourcing a Desktop AC/DC Power Adapter: What OEM Buyers Need to Specify Before Ordering
Medical Power Solutions: 5 Critical Factors for Safe and Reliable Adapters and Battery Chargers
Note: Inlet descriptions are general selection guidance. Specific current ratings, temperature ratings, cord specifications, and certification requirements should be verified against applicable standards, component documentation, and product approvals for the intended market.